Teracom TSF400-0, Water Leak Detector With Digital Output
Teracom TSF400-0, Water Leak Detector With Digital Output
The TSF400-0 is a waterproof water-leak detector designed for early detection of unwanted water presence in technical and industrial environments. It is suitable for installation on floors, in drainage trays, or inside equipment enclosures where water ingress must be detected quickly and reliably. The detector provides an N-channel open-drain digital output, allowing straightforward integration with PLCs, controllers, and building automation systems. The device is capable of responding to very small amounts of water, including slight floor wetting or residual moisture, such as after cleaning. The TSF400-0 is intended for continuous operation in applications where reliable water-leak detection is required to protect equipment and infrastructure.
Detection principle and electrode layout
The bottom surface of the TSF400-0 enclosure contains five electrodes used for water detection. The central electrode is the active sensing element, while the four surrounding electrodes are connected to ground. When the device is placed on the floor, the electrodes come into contact with the surface. The presence of water forms a conductive path between the central electrode and any of the surrounding ground electrodes, which triggers the detector and changes the output state. The electrode arrangement allows reliable detection of water from any direction around the device.
Features:
• Early leak detection
• Wide power supply range
• N-channel open-drain output
• LED status indicator
• Rugged IP65 enclosure
• Maintenance-free design
• Compact and easy to install
• Versatile applications
Applications:
• Leak detection in server rooms, UPS rooms and telecom shelters;
• HVAC drip trays, cooling/condensation lines;
• Under-floor and raised-floor monitoring;
• Domestic and commercial flood-alert systems.
| Specifications | |
| Physical characteristics | |
| Dimensions | 88 x 17 x 46 mm |
| Weight | 115 g |
| Environmental limits | |
| Operating temperature range | 0 to 50 °C |
| Operating relative humidity range | 10 to 90 %RH (non-condensing) |
| Storage temperature range | -20 to 60 °C |
| Storage relative humidity range | 10 to 90 %RH (non-condensing) |
| Ingress protection | IP65 |
| Power requirements | |
| Operating voltage range (including -15/+20% according to IEC 62368-1) | 4.5 to 26 VDC |
| Current consumption | 5 mA @ 12 VDC |
| Output type |
|
| N-channel open-drain | active-LOW |
| Output states | |
| Water absent | output active (LOW) |
| Water present | output inactive (OPEN) |
| Output ratings | |
| Maximum output rating | 30 VDC / 100 mA |
| Cable length | 3 meters |